Skip to main content

When echo gets in the way: physiological factors affecting Doppler data

Summary

Transthoracic echocardiography (TTE) is widely used as a pre-operative screening tool. It can provide extensive information about cardiac function and underlying pathology, which could influence decisions regarding surgery. This patient was referred for TTE as part of pre-op screening, as he had a biological prosthetic aortic valve. This was a rare case where misleading TTE measurements inadvertently led to the patient being referred for transcatheter aortic valve implantation (TAVI), which delayed non-cardiac surgery.

References

  1. Pibarot P, Dumesnil JG. Prosthetic heart valves: selection of the optimal prosthesis and long-term management. Circulation 2009 119 1034–1048. (https://doi.org/10.1161/CIRCULATIONAHA.108.778886)

    Article  Google Scholar 

  2. Vesely I, Barber JE, Ratliff NB. Tissue damage and calcification may be independent mechanisms of bioprosthetic heart valve failure. Journal of Heart Valve Disease 2001 10 471–477.

    CAS  Google Scholar 

  3. Sacks MS, Schoen FJ. Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valves. Journal of Biomedical Materials Research 2002 62 359–371. (https://doi.org/10.1002/jbm.10293)

    Article  CAS  Google Scholar 

  4. Schoen FJ, Fernandez J, Gonzalez-Lavin L, Cernaianu A. Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses (emphasis on progressive structural deterioration). Circulation 1987 76 618–627. (https://doi.org/10.1161/01.cir.76.3.618)

    Article  CAS  Google Scholar 

  5. Walley VM, Keon WJ. Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves. Journal of Thoracic and Cardiovascular Surgery 1987 93 925–933. (https://doi.org/10.1016/S0022-5223(19)37054-0)

    Article  CAS  Google Scholar 

  6. Metivier F, Marchais SJ, Guerin AP, Pannier B, Gérard M. Pathophysiology of anaemia: focus on the heart and blood vessels. Nephrology Dialysis Transplantation 2000 15 (Supplement_3) 14–18. (https://doi.org/10.1093/oxfordjournals.ndt.a027970)

    Article  Google Scholar 

  7. Gómez M, Ble M, Cladellas M, Molina L, Comín-Colet J, Enjuanes C, Roqueta C, Soler C, Bruguera J. Effect of correction of anemia on echocardiographic and clinical parameters in patients with aortic stenosis involving a three-cuspid aortic valve and normal left ventricular ejection fraction. American Journal of Cardiology 2015 116 270–274. (https://doi.org/10.1016/j.amjcard.2015.04.020)

    Article  Google Scholar 

  8. Reddy YNV, Melenovsky V, Redfield MM, Nishimura RA, Borlaug BA. High-output heart failure: a 15-year experience. Journal of the American College of Cardiology 2016 68 473–482. (https://doi.org/10.1016/j.jacc.2016.05.043)

    Article  Google Scholar 

Download references

Funding

This work did not receive any specific grant from any funding agency in the public, commercial or not-for-profit sector.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Jose BSc BSE.

Rights and permissions

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.(http://creativecommons.org/licenses/by/4.0/), which permits use, duplication, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jose, J., Randall, K., Baron, J. et al. When echo gets in the way: physiological factors affecting Doppler data. Echo Res Pract 7, K11–K16 (2020). https://doi.org/10.1530/ERP-20-0006

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1530/ERP-20-0006

Key Words