Skip to main content

Left ventricular speckle tracking echocardiographic evaluation before and after TAVI

Abstract

Aims: To assess left ventricular (LV) function before and after transcatheter aortic valve implantation (TAVI) using conventional echocardiographic parameters and global longitudinal LV strain (GLS) and compare outcomes between Edwards S3 and Evolut R valves.

Methods and results: Data were collected for consecutive patients undergoing TAVI at Hammersmith hospital between 2015 and 2018. Of the 303 patients, those with coronary artery disease and atrial fibrillation were excluded leading to a total of 85 patients, which constituted our study group. The mean follow-up was 49 ± 39 days. In total, 60% of patients were treated with Edwards S3 and 40% Evolut R. TAVI resulted in an early improvement of GLS (−13.96 to −15.25%, P = 0.01) but not ejection fraction (EF) (47.6 to 50.1%, P = 0.09). LV mass also improved, especially in patients with marked baseline LV hypertrophy (P < 0.001). There were no appreciable differences of LV function improvement and overall LV remodelling after TAVI between the two types of valves used (P = 0.14).

Conclusions: TAVI results in reverse remodelling and improvement of GLS, especially in patients with impaired baseline LV function. There were no differences in the extent of LV function improvement between Edwards S3 and Evolut R valves but there was a greater incidence of aortic regurgitation with Evolut R.

References

  1. Thaden JJ, Nkomo VT, Enriquez-Sarano M. The global burden of aortic stenosis. Progress in Cardiovascular Diseases 2014 56 565–571. (https://doi.org/10.1016/j.pcad.2014.02.006)

    Article  Google Scholar 

  2. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. New England Journal of Medicine 2010 363 1597–1607. (https://doi.org/10.1056/NEJMoa1008232)

    Article  CAS  Google Scholar 

  3. Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR, Fontana GP, Dewey TM, Thourani VH, Pichard AD, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. New England Journal of Medicine 2012 366 1686–1695. (https://doi.org/10.1056/NEJMoa1200384)

    Article  CAS  Google Scholar 

  4. Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. New England Journal of Medicine 2016 374 1609–1620. (https://doi.org/10.1056/NEJMoa1514616)

    Article  CAS  Google Scholar 

  5. Wenaweser P, Stortecky S, Schwander S, Heg D, Huber C, Pilgrim T, Gloekler S, O’Sullivan CJ, Meier B, Jüni P, et al. Clinical outcomes of patients with estimated low or intermediate surgical risk undergoing transcatheter aortic valve implantation. European Heart Journal 2013 34 1894–1905. (https://doi.org/10.1093/eurheartj/eht086)

    Article  CAS  Google Scholar 

  6. Latib A, Maisano F, Bertoldi L, Giacomini A, Shannon J, Cioni M, Ielasi A, Figini F, Tagaki K, Franco A, et al. Transcatheter vs surgical aortic valve replacement in intermediate-surgical-risk patients with aortic stenosis: a propensity score–matched case-control study. American Heart Journal 2012 164 910–917. (https://doi.org/10.1016/j.ahj.2012.09.005)

    Article  Google Scholar 

  7. Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H, O’Hair D, Bajwa T, Heiser JC, Merhi W, Kleiman NS, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. New England Journal of Medicine 2019 380 1706–1715. (https://doi.org/10.1056/NEJMoa1816885)

    Article  Google Scholar 

  8. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, Kapadia SR, Malaisrie SC, Cohen DJ, Pibarot P, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. New England Journal of Medicine 2019 380 1695–1705. (https://doi.org/10.1056/NEJMoa1814052)

    Article  Google Scholar 

  9. Anderson B. A Sonographer’s Guide to the Assessment of Heart Disease, 1st ed. Manly, Australia: MGA Graphics, 2014.

    Google Scholar 

  10. Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, Es GA, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. European Heart Journal 2012 33 2403–2418. (https://doi.org/10.1093/eurheartj/ehs255)

    Article  Google Scholar 

  11. Giannini C, Petronio AS, Talini E, De Carlo M, Guarracino F, Grazia M, Donne D, Nardi C, Conte L, Barletta V, et al. Early and late improvement of global and regional left ventricular function after transcatheter aortic valve implantation in patients with severe aortic stenosis: an echocardiographic study. American Journal of Cardiovascular Disease 2011 1 264–273.

    PubMed  PubMed Central  Google Scholar 

  12. Kempny A, Diller GP, Kaleschke G, Orwat S, Funke A, Radke R, Schmidt R, Kerckhoff G, Ghezelbash F, Rukosujew A, et al. Longitudinal left ventricular 2D strain is superior to ejection fraction in predicting myocardial recovery and symptomatic improvement after aortic valve implantation. International Journal of Cardiology 2013 167 2239–2243. (https://doi.org/10.1016/j.ijcard.2012.06.012)

    Article  Google Scholar 

  13. Schattke S, Baldenhofer G, Prauka I, Zhang K, Laule M, Stangl V, Sanad W, Spethmann S, Borges AC, Baumann G, et al. Acute regional improvement of myocardial function after interventional transfemoral aortic valve replacement in aortic stenosis: a speckle tracking echocardiography study. Cardiovascular Ultrasound 2012 10 15. (https://doi.org/10.1186/1476-7120-10-15)

    Article  Google Scholar 

  14. Løgstrup BB, Andersen HR, Thuesen L, Christiansen EH, Terp K, Klaaborg KE, Poulsen SH. Left ventricular global systolic longitudinal deformation and prognosis 1 year after femoral and apical transcatheter aortic valve implantation. Journal of the American Society of Echocardiography 2013 26 246–254. (https://doi.org/10.1016/j.echo.2012.12.006)

    Article  Google Scholar 

  15. Poulin F, Carasso S, Horlick EM, Rakowski H, Lim KD, Finn H, Feindel CM, Greutmann M, Osten MD, Cusimano RJ, et al. Recovery of left ventricular mechanics after transcatheter aortic valve implantation: effects of baseline ventricular function and postprocedural aortic regurgitation. Journal of the American Society of Echocardiography 2014 27 1133–1142. (https://doi.org/10.1016/j.echo.2014.07.001)

    Article  Google Scholar 

  16. Dimitriadis Z, Scholtz S, Ensminger S, Wiemer M, Fischbach T, Scholtz W, Piper C, Börgermann J, Bitter T, Horstkotte D, et al. Left ventricular adaptation after TAVI evaluated by conventional and speckle-tracking echocardiography. International Journal of Cardiology 2017 228 633–637. (https://doi.org/10.1016/j.ijcard.2016.11.035)

    Article  Google Scholar 

  17. Spethmann S, Baldenhofer G, Dreger H, Stüer K, Sanad W, Saghabalyan D, Müller E, Stangl V, Baumann G, Stangl K, et al. Recovery of left ventricular and left atrial mechanics in various entities of aortic stenosis 12 months after TAVI. European Heart Journal Cardiovascular Imaging 2014 15 389–398. (https://doi.org/10.1093/ehjci/jet166)

    Article  Google Scholar 

  18. D’Ascenzi F, Cameli M, Iadanza A, Lisi M, Zacà V, Reccia R, Curci V, Torrisi A, Sinicropi G, Pierli C, et al. Improvement of left ventricular longitudinal systolic function after transcatheter aortic valve implantation: a speckle-tracking prospective study. International Journal of Cardiovascular Imaging 2013 29 1007–1015. (https://doi.org/10.1007/s10554-012-0175-5)

    Article  Google Scholar 

  19. Lorell BH, Carabello BA. Left ventricular hypertrophy: pathogenesis, detection, and prognosis. Circulation 2000 102 470–479. (https://doi.org/10.1161/01.cir.102.4.470)

    Article  CAS  Google Scholar 

  20. Vizzardi E, D’Aloia A, Fiorina C, Bugatti S, Parrinello G, De Carlo M, Giannini C, Di Bello V, Petronio AS, Curello S, et al. Early regression of left ventricular mass associated with diastolic improvement after transcatheter aortic valve implantation. Journal of the American Society of Echocardiography 2012 25 1091–1098. (https://doi.org/10.1016/j.echo.2012.06.010)

    Article  Google Scholar 

  21. Gotzmann M, Lindstaedt M, Bojara W, Mügge A, Germing A. Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation. American Heart Journal 2010 159 926–932. (https://doi.org/10.1016/j.ahj.2010.02.030)

    Article  Google Scholar 

  22. Tzikas A, Geleijnse ML, Van Mieghem NM, Schultz CJ, Nuis RJ, van Dalen BM, Sarno G, van Domburg RT, Serruys PW, de Jaegere PPT. Left ventricular mass regression one year after transcatheter aortic valve implantation. Annals of Thoracic Surgery 2011 91 685–691. (https://doi.org/10.1016/j.athoracsur.2010.09.037)

    Article  Google Scholar 

  23. Hess OM, Ritter M, Schneider J, Grimm J, Turina M, Krayenbuehl HP. Diastolic stiffness and myocardial structure in aortic valve disease before and after valve replacement. Circulation 1984 69 855–865. (https://doi.org/10.1161/01.cir.69.5.855)

    Article  CAS  Google Scholar 

  24. Ben-Shoshan J, Konigstein M, Zahler D, Margolis G, Chorin E, Steinvil A, Arbel Y, Aviram G, Granot Y, Barkagan M, et al. Comparison of the Edwards SAPIEN S3 versus Medtronic Evolut-R devices for transcatheter aortic valve implantation. American Journal of Cardiology 2017 119 302–307. (https://doi.org/10.1016/j.amjcard.2016.09.030)

    Article  Google Scholar 

  25. Enríquez-Rodríguez E, Amat-Santos IJ, Jiménez-Quevedo P, Martín-Morquecho I, Tirado-Conte G, Pérez-Vizcayno MJ, Gómez de Diego JJ, Arnold R, Aldazábal A, Rojas P, et al. Comparison of the hemodynamic performance of the balloon-expandable SAPIEN 3 versus self-expandable Evolut R transcatheter valve: a case-matched study. Revista Espanola de Cardiologia 2018 71 735–742. (https://doi.org/10.1016/j.rec.2017.10.025)

    Article  Google Scholar 

  26. Chieffo A, Buchanan GL, Van Mieghem NM, Tchetche D, Dumonteil N, Latib A, Van der Boon RMA, Vahdat O, Marcheix B, Farah B, et al. Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic corevalve revalving system devices: a multicenter collaborative study: the PRAGMATIC plus initiative (Pooled-RotterdAm-Milano-Toulouse in Collaboration). Journal of the American College of Cardiology 2013 61 830–836. (https://doi.org/10.1016/j.jacc.2012.11.050)

    Article  Google Scholar 

Download references

Funding

This review did not receive any specific grant from any funding agency in the public, commercial or not-for-profit sector.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vasiliki Tsampasian MSc MRCP.

Rights and permissions

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.(http://creativecommons.org/licenses/by/4.0/), which permits use, duplication, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tsampasian, V., Panoulas, V., Jabbour, R.J. et al. Left ventricular speckle tracking echocardiographic evaluation before and after TAVI. Echo Res Pract 7, 29–38 (2020). https://doi.org/10.1530/ERP-20-0009

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1530/ERP-20-0009

Key Words